Concentrate slurry leaving a mineral processing plant typically carries 70–85% moisture, and tailings slurry runs wetter still. Without dewatering, concentrate costs climb at the transport, sales and smelting stages, while tailings discharged as-is add load to the tailings storage facility and amplify environmental risk. Dewatering is not a stage a flowsheet can skip.
Each unit has a limit. A thickener takes high tonnage but returns limited underflow density. A filter reaches low cake moisture but handles fine, sticky material poorly and blinds easily. A filter press dewaters thoroughly, yet runs batchwise at a higher unit processing cost. Selection is therefore an exercise in balance: match the configuration to ore properties, size distribution and downstream moisture limits, and weigh dewatering performance against operating cost.
Concentrate dewatering serves product quality, transport and downstream smelting, where the governing metric is cake moisture. Dry tailings stacking prioritises stack stability, safety, and environmental compliance, along with closed-circuit water recovery. Both duties draw on thickening and filtration equipment, but the configuration emphasis differs.
Selection begins with establishing particle size distribution, feed density, return water quality, stacking method, site conditions and environmental requirements. Where coarse particles dominate and fines and clay are low, a dewatering screen can carry the duty continuously. Where fines and clay dominate, thickeners and filter presses do most of the work.

Conveyor gallery for the dewatering circuit
Equipment should not be sized directly from a throughput table. Particle size analysis, static and dynamic settling tests, compression tests and shear tests establish settling rate, underflow density and transport behaviour — the basis for every equipment parameter.
A mineral processing plant normally works with four dewatering units: thickener, dewatering screen, filter and filter press. They cover pre-concentration, deep dewatering and continuous coarse dewatering, and are combined according to material properties.
A thickener settles solids by gravity to form an underflow, while clear water reports to the peripheral overflow and returns to the circuit. Underflow solids typically rise from about 20% to 40–60% by weight, cutting the load on downstream filtration or pressing. A high-rate thickener doses flocculant at the feed point, binding fines into flocs; as those flocs enter the sludge blanket, the bed itself acts as a filter, yielding clearer overflow and denser underflow.

Thickener tank
Applications:
Conventional rake thickeners are simple and low in capital cost, but require a large footprint.
High-rate thickeners deliver higher throughput per unit area and need a flocculant dosing system.
Lamella thickeners raise capacity by adding settling area.
Deep cone thickeners use a deep compression zone and hydrostatic head to produce high-density underflow, suited to dry stacking and high-density transport.
Selection:
Settling area is the governing parameter, calculated as feed solids divided by throughput per unit area. Unit-area throughput must come from settling tests.
Centre drive suits smaller tank diameters; peripheral drive suits larger tanks.
Operation must guard against rake bogging, cloudy overflow and underflow density swings, any of which destabilises the downstream filter press cycle.

Steel access bridge spanning a circular thickener tank
Thickener underflow still requires filtration or pressing to reach transport or dry-stacking moisture.
A vacuum filter suits coarse concentrate at high tonnage. It runs continuously and is simple to operate, but cake moisture is higher and filtrate may need clarification.
A ceramic disc filter combines capillary action in microporous ceramic plates with vacuum differential. Cake moisture typically sits at 8–15% with clear filtrate, which suits fine concentrate — provided plates are kept clean and regenerated to prevent blinding.

High-rate thickener with agitators and pumps, installed indoors on a compact footprint
A filter press separates solids from liquid by pressure differential, cycling through feed, squeezing, cake discharge and washing. A chamber filter press runs at 0.6–1.0 MPa feed pressure and delivers about 15–20% cake moisture, suited to tailings. A membrane filter press adds a second pressure stage at 1.0–2.0 MPa and reaches about 12–15%, which better serves concentrate held to tight moisture limits.

Chamber filter presses in row, with feed pumps and operating platform
Filter press feed density is normally held at 40–60%. Feed pressure, squeeze pressure and cycle time must be set from filtration tests; more pressure and longer cycles do not automatically improve results. Filter cloth must match particle size, corrosivity and filtrate clarity, with service life tracked. Because a filter press runs batchwise, an agitated buffer tank is required to absorb continuous feed.
A dewatering screen uses two self-synchronising motors driving counter-rotating exciter groups, giving the screen box linear motion. Vibration breaks the surface tension of water so that moisture passes the deck, while fines are retained and build a filter bed.

Dewatering screen driven by two self-synchronising motors, high frequency and low amplitude
Applications:
Dewatering screens serve tailings, coal slurry and washed sand, handling dewatering, desliming and media recovery with continuous operation, high capacity and low noise.
For dry tailings stacking, expect 15–20% moisture in the discharge. Actual results depend on feed density, size distribution and panel aperture.
Material high in fines or clay, or prone to blinding, should not rely on a dewatering screen alone for dry stacking.
Selection:
Sizing is based on slurry flow and density, not dry tonnage alone.
High-frequency, low-amplitude excitation is the norm, with deck inclination typically -5° to 0°. A negative angle reduces water carry-over.
Polyurethane slotted panels are standard. An aperture that is too wide loses fines; one that is too narrow blinds the panel. Screen box strength, spring assemblies and the collection launder all belong on the inspection list.
Capital comparison should cover the whole dewatering line, not the main machine alone.
A thickener brings a flocculant dosing system. A dewatering screen brings panel replacement plus upstream and downstream classification. A filter press brings feed pumps, buffer tank, filter cloth and cake handling on top of the unit itself. Filtration area, plate material and automation level all move filter press cost, and at equal size a membrane unit costs more than a chamber unit.

Complete dewatering line in 3D — thickening, screening, pressing and conveying
On energy, thickeners and dewatering screens run continuously at a steady load. Filter press power goes mainly to feed and squeeze pumps and varies with cycle.
Ceramic disc filters typically draw less power. Vacuum filters draw more, because of the vacuum pump.
Once cake reaches a compacted state, additional pressure mostly adds energy draw and equipment load, with moisture improvement flattening out.
Water recovery also depends on the system. Thickener overflow, filter press filtrate and ceramic filter filtrate are clear enough to return to grinding and flotation. Vacuum filter filtrate, with higher solids content, needs clarification first.
Where thickening, filtration and return-water systems are properly matched, water recovery can reach a reference value of 80–90% of consumption. Actual reuse levels must be confirmed through a plant-wide water balance.
Concentrate dewatering: thickener plus filter or filter press.
Dry tailings stacking, fine high-clay material: thickener plus filter press — a simple flowsheet.

Coarse size distribution: hydrocyclone, dewatering screen, thickener and filter press in a split circuit. Cyclone underflow goes straight to the dewatering screen for dry stacking. Overflow thickens and is then pressed. Cakes combine for stacking, while overflow and filtrate return to the plant.
In short, thickeners, dewatering screens, filters and filter presses do not replace one another. They carry pre-concentration, continuous coarse dewatering and deep dewatering as separate duties.
Particle size distribution, clay content, slurry density and water recovery requirements differ from deposit to deposit. Testwork therefore comes first. Settling and filtration tests, together with a water balance, define the flowsheet and the equipment selection, balancing concentrate quality, tailings disposal, water reuse and operating cost.
It depends on the unit. A ceramic disc filter typically reaches 8–15% cake moisture. A chamber filter press delivers about 15–20%, a membrane filter press about 12–15%, and a dewatering screen 15–20% on dry-stacked tailings. A thickener does not dry the product; it raises underflow solids from about 20% to 40–60% and reduces the load on the equipment downstream.
When coarse particles dominate and fines and clay content are low. Material high in fines or clay, or prone to blinding, should not rely on a dewatering screen alone for dry stacking, because discharge moisture depends on feed density, size distribution and panel aperture.
Where thickening, filtration and return-water systems are properly matched, water recovery can reach a reference value of 80–90% of consumption. Actual reuse levels must be confirmed through a plant-wide water balance.

Zimbabwe 500 t/d gold project, mining and tailings — thickening and water recovery facilities

Guinea 15,000 t/d gold plant — thickener cluster running in parallel

Pakistan 1,500 t/d copper plant — flotation bank

Mongolia 800 t/d fluorspar plant — flotation and filtration in line

Mongolia 3,500 t/d iron plant — structural steelwork under construction

Henan 1,500 t/d polymetallic plant — aerial view of the site
Share your project details and our engineers will get back to you shortly.